| △Applicable medium | Liquid, Gas, Steam |
| △Measuring range | See technical data for more information |
| △Nominal diameter: | DN15~DN150 (Wafer) |
| DN15~DN300 (Flange connection), Customizable |
| △Accuracy | Liquid: ±0.75% of of measured flow rate |
| Gas and steam: ±1% of measured flow rate |
| See reference condition in page 3. |
| △Repeatability | ±0.15% |
| △Operating voltage | Pulse output model: +12VDC, +24VDC selectable |
| Current output model: 4 ~ 20mA.DC, +24VDC |
| On-site display model: integrated 3.6v Lithium-ion battery, battery life: 2 year life. (Customizable) |
| △Output | Pulse: 0.1 ~ 5000Hz |
| 2-wire output: 4 ~ 20mA. (DC) |
| △Operating pressure | 1.6Mpa, 2.5Mpa, 4.0Mpa. Customization available for high requirement. |
| △Medium Temp. | Standard Model: `-40℃~130℃ |
| High Temp. Model: `-40℃~250℃ |
| Explosion-proof Model: ‘-40℃~80℃ |
| △Ambient Temp. | -30℃~60℃ for Explosion-proof model; 40℃~85℃ for others |
| △Ambient Humidity | 5%…95% |
| △Protection class | IP65, IP67 selectable |
| △Housing material | Carbon steel or stainless steel |
| △Explosion-proof | Explosion-proof model: ExdⅡBT5 |
| △Electrical connection | M20×1.5 |