Input Measuring variable position Stroke length 50…2500 mm Output 1. Voltage 0…10 VDC or 10…0 VDC, 0…10 VDC and 10…0 VDC (controller input resistance RL > 5 kOhms) 2. Current 4…20 mA or 20…4 mA (min/max. load: 0/500 Ohms) 3. Start/Stop RS-422 differential signal additionally available: serial parameter upload of stroke length, offset, gradient, status and manufacturer number Accuracy Resolution analog: infinite start/stop: controller dependent Linearity 1 < ± 0.02 % F.S. (minimum ± 60 μm) Repeatability < ± 0.005 % F.S. (minimum ± 20 μm) Update time, stroke dependent analog: < 3 kHz / digital: controller dependent Ripple analog: < 0.01 % F.S. / digital: controller dependent Operating conditions Mounting position any Magnet speed any Operating temperature -40…+75 °C Dew point, humidity 90 % rel. humidity, no condensation Ingress protection 2 IP67, IP69K if mating cable connector is correctly fitted Shock test 100 g (single shock) IEC-Standard 60068-2-27 Vibration test 15g / 10…2000 Hz IEC-Standard 60068-2-6 (resonance frequencies excluded) EMC test electromagnetic emission EN 61000-6-4 (for use in industrial environment) electromagnetic susceptibility EN 61000-6-2 the sensor meets the requirements of the EC directives and is marked with CE Design / Material Sensor housing stainless steel 1.4305 / AISI 303; stainless steel 1.4404 / AISI 316L Rod stainless steel 1.4306 / AISI 304L; stainless steel 1.4404 / AISI 316L for Ø 10 mm rod only Pressure rating 7 mm rod: 300 bar, 450 bar peak 10 mm rod: 350 bar, 530 bar peak Position magnet U-magnet, PA-Ferrite Installation Mounting type threaded flange M18×1.5 or 3/4″ – 16 UNF – 3A Mounting position any Electrical connection Connection type 5 pin connector M12 (analog); 8 pin connector M12 (start/stop) Supply voltage 24 VDC (+20 % / -15 %) Current consumption 50…140 mA (digital 50…100 mA) Ripple < 0.28 Vpp Electric strength 500 VDC (DC ground to machine ground) Polarity protection up to -30 VDC Overvoltage protection up to 36 VDC
|