Input Measured value Position Stroke length 25…2000 mm Output Linearity ≤ ±0.01% F.S. (minimum 40 μm) Outputs: Absolute SSI: (Synchronous Serial Interface) Absolute calculation time: 1 ms Resolution: 1 μm Incremental (analog) 1 Vpp sin/cos Signal period: 20 μm or 50 μm Cuttoff frequency: >100 kHz Measuring step: 1 μm Incremental (digital) TTL A/B quadrature Signal period: 1, 5, 10, 20, 50 μm Cutoff frequency: >250 kHz Measure step: 1 μm Operating conditions Operating temperature −40…+85 °C Relative humidity 90 % no condensation Temperature coeffi cient < 15 ppm/°C Ingress protection IP67, when appropriate connectors are correctly fi tted Shock test 100 g, IEC standard EN 60068-2-27 Vibration test 15 g / 20…2000 Hz (resonance frequency excluded), IEC standard EN 60068-2-6 EMC test Electromagnetic emission: IEC 61000-6-3:2011 Electromagnetic susceptibility: IEC 61000-6-2:2005 The sensors meets the requirements of the EC directives and is marked with CE Design, material Profile Aluminum Magnet PA6 GF30 Electrical connection Connection type 8-pin (M12) male connector and 12-pin (M12) male connector Operating voltage 24 VDC (+20% / −15%) Current drain < 110 mA (typical)
|